دانلود رایگان مقاله لاتین میکرو ct برای آزمایش غیر مخرب از سایت الزویر


عنوان فارسی مقاله:

استفاده از میکرو CT برای آزمایش های غیر مخرب یک افزودنی تولیدشده جزء تیتانیوم


عنوان انگلیسی مقاله:

Application of microCT to the non-destructive testing of an additive manufactured titanium component


سال انتشار : 2015



برای دانلود رایگان مقاله میکرو ct برای آزمایش غیر مخرب اینجا کلیک نمایید.





مقدمه انگلیسی مقاله:

1. Introduction

Additive Manufacturing (AM) has made significant progress in recent years, allowing complex parts to be manufactured layer by layer even in metals, with excellent material properties [1]. X-ray micro computed tomography (microCT) is a non-destructive testing method which has in recent years changed from a qualitative imaging to a quantitative measurement method in various applications, and especially in materials sciences [2,3]. MicroCT has been used successfully to measure the physical density of objects, using a calibration set of known samples of the same material as shown in [4] and quantitative and simple porosity analysis is possible providing information on pore sizes, shapes and more [5]. MicroCT has been applied to AM parts in various forms. Some preliminary results demonstrating the visualization of defects including porosity in AM components were reported in [6]. In another study, the porosity structures in parts built with improper settings were investigated [7]. In this work, the average porosity ranged from 0.1–0.5%, and large pores were observed which followed the build direction and may be attributed to the electron beam raster and overlap pattern. This was followed by more recent reports of the porosity distribution as a function of build strategy for electron beam melted samples with average porosity < 0.2% [8]. In another study, similar porosity images from microCT were reported at levels above 0.2% average porosity [9,10]. Very recent work reports similar images and may indicate that the porosity structure depends on the build direction [11]. Other applications of the use of microCT to characterize AM parts include the comparison of the part to its design model [12] and the characterization of surface roughness of such parts [13]. In the present work, the aim is to demonstrate a specific type of defect present at very low average porosity levels below 0.01%, and which does not follow the build direction as in some other reported examples. We also demonstrate how this porosity structure changes after Hot Isostatic Pressing (HIP) treatment of the same sample.



برای دانلود رایگان مقاله میکرو ct برای آزمایش غیر مخرب اینجا کلیک نمایید.






کلمات کلیدی:

Application of micro-CT in small animal imaging - ScienceDirect www.sciencedirect.com/science/article/pii/S1046202309002023 by SJ Schambach - ‎2010 - ‎Cited by 194 - ‎Related articles Over the past decade, the number of publications using micro-computed tomography (μCT) imaging in preclinical in vivo studies has risen exponentially. ... Small animal imaging has a vital role in understanding these models and a key role in phenotyping, as well as drug development ... Application of micro-CT in small animal imaging. - NCBI https://www.ncbi.nlm.nih.gov/pubmed/19706326 by SJ Schambach - ‎2010 - ‎Cited by 194 - ‎Related articles Methods. 2010 Jan;50(1):2-13. doi: 10.1016/j.ymeth.2009.08.007. Epub 2009 Aug 23. Application of micro-CT in small animal imaging. Schambach SJ(1), Bag S ... Current status of developments and applications of micro-CT. https://www.ncbi.nlm.nih.gov/pubmed/21756145 by EL Ritman - ‎2011 - ‎Cited by 98 - ‎Related articles Aug 15, 2011 - Use of microscopic computed-tomography (micro-CT) scanning continues to grow in biomedical research. Laboratory-based micro-CT ... SkyScan micro-CT application examples - Bruker microCT bruker-microct.com/applications/all_examples.htm microCT and nano-CT application examples. ... Application examples; <<< other direct links here. select by application area : select by scanner : home · news ... Microcomputed tomography: approaches and applications in ... https://stemcellres.biomedcentral.com/articles/10.1186/scrt534 by JD Boerckel - ‎2014 - ‎Cited by 11 - ‎Related articles Dec 29, 2014 - Microcomputed tomography (microCT) has become a standard and essential tool for quantifying structure-function relationships, disease ... [PDF]Application of CT scanning in Industry: Nano and Micro-CT for ... https://www.dti.dk/_/media/52347_Bart_Pauwels_SkyScan.pdf Oct 25, 2010 - Application of CT scanning in Industry: Nano and Micro-CT for Materials Science. Danish Technological Institute, 31/5/2011 ... Application of Micro-CT and MRI in Clinical and Preclinical Studies of ... link.springer.com/chapter/10.1007%2F978-3-540-45456-4_24 by YB Jiang - ‎2007 - ‎Cited by 4 - ‎Related articles Micro-CT is also useful for studying osteoporosis in mice and phenotypes of mice with gene manipulation. Micro-CT can quantify osteogenesis in mouse Ilizarov ... Application of Nano-CT and High-Resolution Micro-CT to Study Bone ... link.springer.com/chapter/10.1007%2F978-3-540-45456-4_19 by PL Salmon - ‎2007 - ‎Cited by 10 - ‎Related articles Abstract. The application of micro-CT technology to biomedical and bone research is considerable and growing. This chapter focuses on applications requiring ... Biomedical microCT : Applications : Scanco Medical: micro CT ... www.scanco.ch/en/applications/biomedical.html All our microCT systems are calibrated for measurement of biological tissue densities, ... using our devices can be found in our collection of Application Notes.