دانلود رایگان مقاله لاتین تحلیل شکست فولاد زنگ نزن از سایت الزویر
عنوان فارسی مقاله:
تجزیه و تحلیل شکست فولاد زنگ نزن 316L فمور ارتوپدی کاشت
عنوان انگلیسی مقاله:
Failure analysis of a 316L stainless steel femoral orthopedic implant
سال انتشار : 2016
برای دانلود رایگان مقاله تحلیل شکست فولاد زنگ نزن اینجا کلیک نمایید.
مقدمه انگلیسی مقاله:
1. Introduction
In orthopedic surgery, locking compression plates (LCP) are commonly used to stabilize fractured bone parts together. LCPs are generally manufactured with combi-holes that aim to accommodate two types of screws: locking and compression screws [1]. The choice of screws allows orthopedists to customize their installation method to balance compression and locking capability. This balance is necessary to provide angular stability and to limitthe contact with the bone to preserve the blood supply and the tissue viability. Compression is known to produce the strain needed for the bone during the healing process of reconstruction [1]. Even though LCPs show uncontradicted advantages for healing fractured bones, their mechanical stability is technically difficult to maintain [2]. In 2003, a study involving 130 fractures repaired with a LCPshowed 27 complications, with 18 of them requiring a second intervention [3]. The most common complications were nonunion ofthe bone, loosening ofthe implant, breakage ofthe implant or an additional bone fracture. The objective ofthis study is to understand the failure mechanism of a specific LCP that failed prematurely. The studied systemis composed of a LCPfixed to a broken femur using bothlocking and compressionscrews.Apicture ofthe broken implant is shown in Fig. 1. The distal extremity is situated closer to the knee and on the opposite side, the proximal extremity is closer to the hip. The failure analysis of the LCP was performed in 3 steps: material characterization (Section 4.1), fractographic analysis (Section4.2), andpreliminaryfiniteelement analysis (FEA) ofthe stresses seenbythe implant(Section5). A discussion explaining the failure mechanism and the root causes of failure is proposed in Sections 6 and 7.
برای دانلود رایگان مقاله تحلیل شکست فولاد زنگ نزن اینجا کلیک نمایید.
کلمات کلیدی:
Failure analysis of a 316L stainless steel femoral ... - ResearchGate https://www.researchgate.net/.../290026187_Failure_analysis_of_a_316L_stainless_steel... This study presents a failure analysis of a femoral orthopaedic implant. This implant is a locking compression plate that was fixed to a broken femur using two ... Failure Analysis of a 316L Stainless Steel Femoral Orthopedic ... - Scribd https://www.scribd.com/.../Failure-Analysis-of-a-316L-Stainless-Steel-Femoral-Orthop... Case Studies in Engineering Failure Analysis journal homepage: www.elsevier.com/locate/csefa. Case study. Failure analysis of a 316L stainless steel femoral ... Failure Analysis of a 316L Stainless Steel Femoral Orthopedic ... - Scribd https://pt.scribd.com/.../Failure-Analysis-of-a-316L-Stainless-Steel-Femoral-Orthopedic-I... Failure Analysis of a 316L Stainless Steel Femoral Orthopedic Implant. 9 pages. For unlimited access and the best reading experience, open in our app. [PDF]Failure Analysis of 316L Air Cooler Stainless Steel Tube in a Natural ... www.electrochemsci.org/papers/vol10/100907606.pdf by AB Radwan - 2015 - Cited by 1 - Related articles Jul 28, 2015 - This work presents an analysis of the failure behavior of 316L SS air chiller tube with a peripheral crack used in a Qatari gas company in Qatar. Failure analysis of explanted 316L stainless steel sternal wires ... https://tmu.pure.elsevier.com/.../failure-analysis-of-explanted-316l-stainless-steel-stern... by CM Shih - 2006 - Cited by 1 - Related articles Failure analysis of explanted 316L stainless steel sternal wires shows the need for improved sternal wire quality. The analysis is done by showing the wire end ... Failure analysis of explanted 316L stainless steel sternal wires ... https://tmu.pure.elsevier.com/.../failure-analysis-of-explanted-316l-stainless-steel-stern... by CM Shih - 2005 - Cited by 1 - Related articles This paper seeks to classify and understand the mechanisms of surface damages and fracture mechanisms of sternal wires. Explanted stainless steel sternal ... [PDF]FRACTOGRAPHIC INVESTIGATION OF FAILURE IN STAINLESS ... facta.junis.ni.ac.rs/me/me201201/me201201-02.pdf tenitic stainless steel is one of the most important materials for fracture fixation .... 1 Six investigated plates with cut parts for SEM analysis of failure surface ... with the standard chemical composition for 316L austenitic stainless steel [11].