دانلود رایگان مقاله لاتین آرتروسکوپی از سایت الزویر


عنوان فارسی مقاله:

آرتروسکوپی شعاعی قطع و برداشت ایمپلنت سر


عنوان انگلیسی مقاله:

Arthroscopic Radial Head Implant Removal and Resection


سال انتشار : 2016



برای دانلود رایگان مقاله آرتروسکوپی اینجا کلیک نمایید.





مقدمه انگلیسی مقاله:

1. Introduction

The cartilage rim is excised with a combination of punches, graspers (Acufex; Smith & Nephew), and small-joint shavers (Arthrex). Loose pieces of the rim may persist as loose bodies, and meticulous removal is crucial (Fig 6). Adequacy of resection is confirmed by (1) arthroscopic visualization of an adequate radiocapitellar space, which usually equates to 2 breadths of a 4-mm burr; (2) arthroscopic visualization of the cortical borders of the radial shaft that is distal to the resected radial head; and (3) fluoroscopic visualization of resection of the entire radial head (Figs 7 and 8). A bulky dressing and sling are used in the postoperative period for 2 to 3 days. The rehabilitation protocol involves early passive and active range-ofmotion exercises (weeks 1 through 6) and simultaneous gradual strengthening. Achievement of full range is dependent on the initial severity of the problem and may vary from 4 to 8 months. Light work is permitted after 6 weeks, and a return to heavy work is permitted only after 3 months (Fig 9).



برای دانلود رایگان مقاله آرتروسکوپی اینجا کلیک نمایید.






کلمات کلیدی:

radial head implants - Wheeless' Textbook of Orthopaedics www.wheelessonline.com/ortho/radial_head_prosthetic_replacement Nov 3, 2015 - metal radial head replacement restored elbow stability when fracture of the radial head occurred in combination with dislocation of elbow ... [PDF]Anatomic Radial Head Solutions Surgical Technique - Acumed www.acumed.net/.../Acumed-SurgicalTechnique-AnatomicRadialHeadSolutions-ELB... Symptomatic replacement after radial head resection. • Revision following failed radial head arthroplasty. In addition to the Anatomic Radial Head System, this ... [PDF]Anatomic Radial Head Brochure and Surgical Technique - Acumed www.acumed.net/system/files/legacy_files/literature/brochure.../ARH_Brochure.pdf replacement. The Acumed® Anatomic Radial Head Prosthesis is designed to provide a precise anatomical implant to replace the patient's native radial head. [PDF]surgical technique - Small Bone Innovations www.totalsmallbone.com/us/pdfs/MKT10414_RevA_rHead_SurgTechnique.pdf Cited by 3 - ‎Related articles the forearm and/or distal and proximal radio-ulnar joints) are compromised, joint instability is noted to increase. Replacement of the radial head is an anatomic ... removal of radial head - Orthopedics - MedHelp www.medhelp.org › Communities › Orthopedics Dec 23, 2008 - I was misdiagnosis for almost a month and a half. Finally I saw another Doctor went ahead and did a radial head replacement with metal that ... [PDF]Short- to Medium-term Outcomes of Radial Head Replacement ... memo.cgu.edu.tw/cgmj/3306/330609.pdf by HY Chien - ‎2010 - ‎Cited by 24 - ‎Related articles Radial head replacement (RHR) is indicated for patients with ... Key words: irreparable radial head fracture, radial head replacement, posttraumatic unstable. Searches related to Radial Head Implant Removal and Resection radial head removal long term effects radial head removal recovery time radial head excision complications radial head excision recovery radial head excision results radial head excision rehab radial head excision surgical technique radial head resection long term outcome